Who runs the program
Lathrop Public Works, 390 Towne Centre Drive, Lathrop, CA 95330, (209) 941-7430, fax (209) 941-7449; Public Works after-hours emergency (209) 992-0028. The code: “Except as otherwise provided herein, the director of public works shall administer, implement, and enforce the provisions of this chapter” (LMC 13.26.010(C)), with interceptor type and capacity “approved by the city building division” (13.26.160(D)(1)). Lathrop’s wastewater is treated at more than one plant: LMC 13.16.250 is titled “User rates for Manteca WQCF, Lathrop WRP-1 (MBR) and Crossroads,” and the City holds an industrial pretreatment interjurisdictional agreement with the City of Manteca (Resolution No. 05-1975). We do not quote that agreement on this site; Public Works can tell you which plant your lateral feeds.
Who is covered
“All food service providers to include restaurants, cafeterias, food preparation facilities, convenience stores preparing fast foods for sale; grocery stores providing cooked foods for sale; and other food preparation facilities” (13.26.160(B)). The chapter’s general discharge limits add a number: fats, oils or greases of animal or vegetable origin “in concentrations greater two hundred (200) mg/l” are prohibited (13.26.020(A)(2)(q), as printed).
When you must install, and what
Two sections say so. The general one: “Grease, oil and sand interceptors shall be provided when, in the opinion of the city, they are necessary for the proper handling of wastewater containing excessive amounts of grease and oil, or sand ... Such interceptors shall be inspected, cleaned, and repaired regularly, as needed, by the user at their expense” (13.26.030(B)(3)). The FOG one: devices “shall be provided by the facility owner, when, in the opinion of the city, they are necessary to prevent grease in excessive amounts from entering the sanitary sewer system,” with “manufacturer’s capacity data and an estimate of the product rate at the facility” submitted for approval (13.26.160(D)(1)). An existing facility can be required to install, modify or replace a device “within ninety (90) days” of written notice on six findings (D)(2): line stoppages or increased sewer maintenance traced to you; no device; an undersized, nonrepairable or defective device; a permitted kitchen-plumbing remodel; a sale or change of ownership; or non-compliant plumbing connections. Plumbing (D)(3): dishwashers only if the interceptor is “properly designed to contain and cool the dishwasher discharge”; garbage disposals and restrooms not; hood washers and food-area floor drains yes; “Sanitary facilities (restrooms) shall not be plumbed to the grease interceptor under any circumstance.” A trap instead of an interceptor only where the kitchen does “not operate a deep fat fryer, a cooking grill and conducts minimal dishwashing” (D)(4). Sizing: the City’s design standards say an on-site grease trap “may be required on service laterals and sized accordingly using the latest edition of the Uniform Plumbing Code (UPC). The City Engineer shall make this requirement on a case-by-case basis.”
The interval: none printed, and what governs instead
LMC 13.26.160(E)(2): “The discharger is responsible for establishing a routine maintenance schedule that includes the routine removal of floatable and settleable solids and cleaning of the interceptors/traps. The maintenance frequency should be such that the interceptor/trap does not allow fats, grease, oils, and food solids from leaving the interceptor and entering the city sewer collection system. The amount of time between pumping and cleaning services is dependent on the volume of wastes discharged, the volume of the interceptor/trap, and the physical integrity of the interceptor/trap structures and piping.” No number, no 25% rule, no plumbing-code interval. What governs is the outcome, grease not leaving the tank, and the City’s remedy if it does: “The city may impose a mandatory pumping and cleaning schedule to assure the proper maintenance of an interceptor not properly maintained by the discharger ... Mandatory service schedules may cover a time period of up to three years” (K)(2). Our schedule for a Lathrop kitchen comes from the depth reading at the first service, working to a 25%-of-depth ceiling as our standard; that is the figure the two codified cities in this county use, not a Lathrop rule, and the receipt says which.
Records
“A copy of the pumping manifest or billing must be retained with the maintenance records,” and each record must carry ten items (E)(3). “Record Retention. All grease interceptor/trap maintenance records shall be retained for a period of not less than three years. These records shall be retained at the food service facility and shall be made available for inspection by the city” (E)(4).
Prohibitions and access
- “The use of chemicals, emulsifying agents, enzymes, microorganisms, and/or other additives that are added to the grease interceptors/traps to reduce or eliminate the pumping and cleaning of the interceptor/trap is prohibited” (I).
- “Failure to grant access may result in the suspension of sewer and water services provided by the city” (J).
- Any Council-approved SSMP requirement “shall be enforceable by the City” under 13.26.100 through 13.26.130 (LMC 13.16.075).
Enforcement and fines
“Failure to comply with the provisions of this chapter is considered a misdemeanor and subject to enforcement actions under the city codes” (K). Unlike Manteca, Lathrop prints the fine in the FOG section: “The city may assess fines to the discharger, not to exceed $1,000 per day per violation, for violations of the city chapter” (K)(4), matching the chapter’s general rule of fines “not to exceed one thousand dollars ($1,000.00) ... assessed on a per violation, per day basis” (13.26.110(F)(1)). Unpaid amounts grow: “after 60 calendar days, be assessed an additional penalty of 25% of the unpaid balance, and interest shall accrue thereafter at a rate of one percent per month. A lien against the user’s property will be sought” (K)(4)(a). And “the city may immediately suspend a discharge and/or water services, after informal notice to the discharger” in an emergency (K)(5).
What we do not quote here
The City’s FOG Enforcement Response Plan (listed as a draft in the SSMP), the Manteca-Lathrop pretreatment agreement, and any Lathrop FOG permit or inspection fee are not quoted on this site; the City’s FOG web page names no interval, permit or fee. Public Works at (209) 941-7430 can tell you what applies at your address.
How we service Lathrop kitchens
Same truck and same standard as Stockton and Manteca: full contents out, walls and piping cleaned, the empty tank inspected for the deficiency list the record requires, refilled. The receipt is written to the ten items, signed by our operator, with a line for your employee’s signature, and carries the percent-full reading the code does not demand but an inspector always asks about. Three years in the folder at the facility.
Lathrop: one call, flat number
Tank size and meals per day. Ten-item receipts, every visit.
Call (209) 292-2953