Who runs the program
City of Manteca Public Works-WQCF Environmental Compliance, 1001 W. Center St, Manteca, CA 95337, (209) 456-8470. The same number is the City’s 24-hour line: “If you experience a sewer blockage or overflow, call the City of Manteca at 209-456-8470, 24 hours a day.” The City’s pages call the rule “ordinance 13.20.110”; it is a section of Chapter 13.20 Industrial Waste, adopted, in the City’s words, “to aid in the prevention of sanitary sewer blockages and obstructions from contributions and accumulation of fats, oils, and greases into the sanitary sewer system from industrial or commercial establishments, particularly food preparation and serving facilities.” Interceptor type and capacity are approved by “the city building division” (13.20.110(D)(1)); enforcement runs through the director of public works under 13.20.090.
Who is covered
“All food service establishments to include restaurants, cafeterias, food preparation facilities, convenience stores preparing fast foods for sale; grocery stores providing cooked foods for sale; and other food preparation facilities” (13.20.110(B)). The definition reaches further than most owners expect: “food courts, food manufacturers with an average daily discharge volume of twenty-five thousand gallons per day or less, food packagers, restaurants, grocery stores, bakeries, lounges, hospitals, hotels, nursing homes, churches, schools, and all other food service facilities not listed in this chapter” (13.20.110(C)).
When you must install, and what
Interceptors or traps “shall be provided by the facility owner, when, in the opinion of the city, they are necessary to prevent grease in excessive amounts from entering the sanitary sewer system,” and prospective trap users “must provide manufacturer’s capacity data and an estimate of the product rate at the facility” (D)(1). An existing facility can be ordered to install, modify or replace a device “within ninety days of written notification” on any of six findings (D)(2): it is “contributing grease and oil in quantities sufficient to cause line stoppages”; it has no device; the device is “undersized, nonrepairable or defective”; a kitchen plumbing remodel needs a building permit; the facility “is sold or undergoes a change of ownership”; or its plumbing connections do not comply. Plumbing rules under (D)(3): dishwashers may connect only if the interceptor is “properly designed to contain and cool the dishwasher discharge”; “Garbage disposals and restrooms should not be plumbed to the grease interceptor”; hood washers and food-area floor drains should be. A trap in place of an interceptor “will only be authorized for those facilities that do not operate a deep fat fryer, a cooking grill and conducts minimal dishwashing” (D)(4).
The interval: you set it, the City can override it
There is no numeric interval and no 25% rule in Manteca’s code. The maintenance standard is (E)(1): devices “shall be continuously maintained in satisfactory and effective operational condition by the discharger at the discharger’s expense.” The schedule is (E)(2): “The discharger is responsible for establishing a routine maintenance schedule that includes the routine removal of floatable and settleable solids and cleaning of the interceptors/traps. The maintenance frequency should be such that the interceptor/trap does not allow fats, grease, oils, and food solids from leaving the interceptor and entering the city sewer collection system.” The code names the variables, “the volume of wastes discharged, the volume of the interceptor/trap, and the physical integrity of the interceptor/trap structures and piping,” and leaves the arithmetic to you.
What governs instead of a number is the City’s power to impose one. Under (K)(1) “the city may issue an order requiring the discharger to conduct interceptor/trap maintenance services within a mandatory time period,” and under (K)(2) “the city may impose a mandatory pumping and cleaning schedule to assure the proper maintenance of an interceptor not properly maintained by the discharger. The cost of the services shall be the direct responsibility of the discharger. Mandatory service schedules may cover a time period of up to three years.” A kitchen that sets and keeps its own schedule never meets (K)(2). We set yours from the depth reading at the first service, working to a 25%-of-depth ceiling as our standard, and the reading on each receipt is the evidence the schedule is working.
Records: ten items, three years, and the mail-in report
Where a service company does the work, “a copy of the pumping manifest or billing must be retained with the maintenance records,” and (E)(3) says what every record must show at minimum. (E)(4): “All grease interceptor/trap maintenance records shall be retained for a period of not less than three years. These records shall be retained at the food service establishment and shall be made available for inspection by the city.”
On top of the code, the City’s Grease Interceptor Pump Out Report form is marked “(MUST BE COMPLETED WITH EVERY PUMP OUT)” and “Must Mail in With Every Pump Out” to the FOG Compliance Program at 1001 W. Center St. It asks for the hauler manifest, depth of grease, depth of water, depth of solids in inches, pump-out method, complete pump or pump-and-return, and gallons transported. That mail-in requirement is the City’s program practice on the form; the code section itself speaks of records kept on the premises. We fill the depth and gallon fields from the truck and hand you the sheet to sign and send. The FOG Program Application asks you to “return to the City of Manteca within 14 days of receiving this application,” certifies that you have read ordinance 13.20.110, and notes that if you have a device “a Grease Interceptor/Trap Certification Form will be required.” Training records: “Must keep Training records for 3 years,” and any FOG spill is reported to Environmental Compliance at 209-456-8470.
Prohibitions
- “Materials removed from waste interceptors/traps shall not be discharged to the city sanitary sewers or storm drains” (F).
- “The use of chemicals, emulsifying agents, enzymes, microorganisms, and/or other additives ... to reduce or eliminate the pumping and cleaning of the interceptor/trap is prohibited” (I).
- Refusing an inspector: “Failure to grant access may result in the suspension of sewer and water services provided by the city” (J).
Enforcement and fines
“Failure to comply with the provisions of this chapter is considered a misdemeanor and subject to enforcement actions under the city codes” (K). Fines run through 13.20.090: “For each violation the offender may receive thirty days in jail or a fine of one thousand dollars, or both. A violation may be recorded for each instance of non-compliance and for each day the noncompliance occurred” (A)(6)(b); civil action carries “a penalty of twenty-five thousand dollars per day for each violation pursuant to California Government Code Section 54740” (A)(6)(c); administrative civil penalties reach $2,000 per day for missing reports, $3,000 per day for missing a compliance schedule, $5,000 per violation per day for a discharge violation, and “ten dollars per gallon for discharges in violation of any suspension, cease and desist order or other orders” (A)(6)(d). The City may also issue wastewater discharge permits to FSEs “either on a case-by-case basis or as part of a general program” (K)(4)(d).
Disposal: the WQCF receiving station
Manteca’s plant takes grease. The ordinance sets the charge: “For each load delivered to the receiving station the charge is one hundred dollars per thousand gallons or part thereof for FOG collected in Manteca and one hundred twenty five dollars per thousand gallons or part thereof for all others,” adjusted by CPI “on March 1st, 2021, and every year thereafter” (L). The current figure is therefore higher than the ordinance text; the WQCF can quote today’s rate. Either way, disposal is a real line inside every honest quote for a Manteca pump-out.
What we do not quote here
The Grease Interceptor/Trap Certification Form, the City’s Grease Interceptor Cleaning Log, the FOG signage sheet, and any FOG permit or inspection fee amount are not quoted on this site. Environmental Compliance at (209) 456-8470 can tell you which forms your facility owes and what, if anything, they cost.
How we service Manteca kitchens
Full contents out, walls and piping cleaned, the empty tank inspected for the deficiency list (E)(3)(e) asks for, refilled. The receipt is written to the ten items above, signed by our operator, with a line for your employee’s signature; the Pump-Out Report’s depth and gallon fields come off the same measurements. Same truck that works Stockton, same standard. Request a quote or call (209) 292-2953.
Manteca: the schedule you set, documented
Tank size and meals per day. Ten-item receipts and the depth reading for the City’s report, every visit.
Call (209) 292-2953