First question: where does your wastewater go?
Unincorporated addresses in French Camp, Flag City, the Delta and the farm belt fall under one of three County instruments, and the answer is on your sewer bill or your parcel. If the bill comes from San Joaquin County Public Works Special Districts, you are in a County Service Area and the Utilities Ordinance and Division 6 apply. If your district’s sewage is treated at the City of Stockton’s Regional Wastewater Control Facility, the County code hands you to Stockton’s rules. If there is no sewer bill, you are on an onsite system and Environmental Health’s OWTS Standards apply.
Who to call. County sewer districts: San Joaquin County Public Works, Special Districts, 1810 E. Hazelton Avenue, Stockton, CA 95205, (209) 468-3000, maintenance issues (209) 468-3090, specialdistricts@sjgov.org, 8am-12pm and 1pm-5pm Monday to Friday; Utility District Maintenance is at 1702 E. Scotts Avenue and runs “3 sewage treatment plants and 9 pumping stations.” Septic parcels and food-facility plan check: Environmental Health Department, 1868 East Hazelton Avenue, Stockton, CA 95205, (209) 468-3420; Liquid Waste Program (209) 468-9850. In the code, “‘Director’ means the Director of the Department of Public Works of the County or an authorized representative” (Ord. Code 5-6000(j)), and interceptor design is “approved by the Environmental Health Division” (5-6406(b)).
Regime 1: a County sewer district
The San Joaquin County Utilities Ordinance (5-3111) governs any “special district empowered to operate and maintain water, storm drainage or sewer facilities, operated by the County including, but not limited to, County Service Areas” (5-3100(b)). Its prohibited-uses section bars from a district sewer “oils, or greases other than normal residential kitchen wastes” (5-3105(I)(c)) and “Waste water from any restaurant, bar, or other kitchen where food is prepared for public consumption unless first directed through an approved grease trap, as required by the Uniform Plumbing Code” (5-3105(I)(f)). Kitchen wastewater may never go to the storm drain (5-3105(II)(e)). Building sewers are inspected by the Building Inspector “as prescribed in the Uniform Plumbing Code” (5-3101).
Where the County treats the sewage, Division 6 adds the interceptor rule, Ord. Code 5-6406 “Grease interceptors”: “Any type of business or establishment such as, but not limited to, restaurants, bakeries, donut shops, takeout or drive-in eating establishments, ice cream or milk drive-in stations, hospitals, hotels, markets, recreation or reception halls, etc., where any grease or other objectionable materials may be discharged into a public or private sewage main or disposal system shall have a grease interceptor” (a). Design is approved by Environmental Health (b). The unit must be “at all times easily accessible for inspection, cleaning and removal of the intercepted grease,” and “may not be installed in any part of a building where food is handled” (c). One interceptor per business, serving only that business (d); remodels for a use needing one trigger the rule (e). Scullery and pot sinks, dishwashers, food waste disposals, soup kettles and food-area floor drains “may be drained into the sanitary waste through the interceptor when approved by the Director,” never toilets or urinals (f). Covers are “one-half inch thick steel plate reinforced to withstand any applied load” and gas-tight (i); outside drainage must be kept out (j); abandoned interceptors are “emptied and filled as required for abandoned septic tanks” (h). Garbage grinders outside a dwelling need a wastewater discharge permit (5-6404).
The interval: none, in any regime
Division 6 says only this about frequency: “The interceptors shall be maintained in efficient operating condition by periodic removal of the accumulated grease. No such collected grease shall be introduced into any drainage piping or public or private sewer” (5-6406(g)). There is no numeric interval, no 25% rule, no record-keeping clause and no plumbing-code section number. The Utilities Ordinance adds nothing on frequency. The septic standards (below) say “a frequency that prevents grease from surfacing or entering into the OWTS.” What governs is the outcome and the inspector: “The County may inspect the facilities of any user” with “ready access at all reasonable times to all parts of the premises” (5-6504), and the Director may issue a cease and desist order requiring compliance “forthwith,” on a schedule, or by remedial action (5-6901). We set a County kitchen’s schedule from the depth reading at the first service, working to a 25%-of-depth ceiling, which is our standard and the figure Stockton and Tracy codify, not a County rule.
One more Division 6 clause worth knowing: “Every user utilizing pretreatment will be required to file a report semiannually which tabulates the quantities and types or residual wastes removed through pretreatment and the location and method of disposal of those residual wastes” (5-6505). An interceptor is pretreatment on its face. Whether Special Districts applies that report to restaurants in County Service Areas is not something we quote on this site; ask at (209) 468-3000. If it does, our receipts, with gallons removed and the disposal site named, are the tabulation.
Civil penalties under Division 6: “a sum not to exceed six thousand dollars ($6,000.00) for each day in which such violation occurs,” owed “to the County or the City of Stockton” (5-6904); and “It is unlawful for any person or entity to intentionally or negligently fail to comply with or violate any provisions of this division” (5-6905).
Regime 2: sewered to Stockton’s plant
Ord. Code 5-6100: “When the wastewater is treated by the City of Stockton Regional Wastewater Treatment Facility, the following provisions of Chapter 7, Part III, of the Stockton Municipal Code shall apply ... The city may bill certain nonresidential users directly for costs associated with permitting, pretreatment or treatment of wastewater discharges. The County may also impose fees and charges for maintenance of the County collection system.” That cross-reference carries Stockton’s old numbering; the City’s FOG rules now sit in SMC Chapter 13.40, three months or 25% whichever first, six-line hauler records, three-year file. If your district drains to Stockton, read the Stockton page as your rule and expect the City, not the County, to bill the pretreatment side.
Regime 3: septic
The County OWTS Standards (Ord. Code 9-1105) prohibit sending into an onsite system “greases other than normal residential kitchen wastes” (1.14(c)) and “Wastewater from any restaurant, bar, or other kitchen where food is prepared for public consumption unless first directed through an approved grease trap, as required by the Uniform Plumbing Code” (1.14(f)). “An appropriately sized and designed grease receptor shall be required for all commercial food establishments or where any activity occurs which produces a grease content over and above the normal grease content found in domestic sewage” (6.2), and “All grease receptors shall be maintained in good working order and shall be pumped at a frequency that prevents grease from surfacing or entering into the OWTS and leach field” (6.3). For small package plants, a receptor “must be installed in front of the wet well (head works)” and be “of sufficient size to retain the grease-laden sewage for a period suitable to remove the grease” (7.10, 7.11). On septic the stakes are the leach field: grease that gets past the receptor does not clear a pipe downstream, it blinds the soil, and that is a replacement, not a jetting.
State law in every regime
Environmental Health’s plan-check guide reminds every food facility of the California Retail Food Code: “CRFC 114201 (a) If provided, a grease trap or grease interceptor shall not be located in a food or utensil handling area unless specifically approved by the enforcement agency. (b) Grease traps and grease interceptors shall be easily accessible for servicing,” and to “Check with local health, building, sanitary or public works agencies” for the sewer-side rule. This page is that check for the County side.
What we do not quote here
Which County Service Areas run sewer service (CSA 31, Flag City, is one), whether the County issues FOG-specific permits or runs a restaurant inspection program, and any County fee amount are not quoted on this site. Special Districts at (209) 468-3000 can answer for sewer parcels; Environmental Health at (209) 468-3420 for septic.
How we service County kitchens
Same truck, same standard: full contents out, baffles and tees checked, refilled, waste manifested to an approved facility and named on the receipt. The receipt also carries the percent-full reading and gallons removed, which is what 5-6505’s tabulation, Stockton’s six-line record or a septic inspector would each want. Tell us the address and whose name is on the sewer bill, and we will tell you which regime you are in before the truck rolls.
County: tell us the address and the bill
Tank size, meals per day, and who bills your sewer. One call sorts the regime and the quote.
Call (209) 292-2953